To begin how is the MBPro2 connected to the VP2? And maybe you could explain what not quite a "typical" setup means?

Obviously with several pressure, temp and humidity sources there can be variations depending on the station setup, sensor mapping etc have you implemented any calibration offsets, factors etc

On the System>Administration>System window how does he Power data: (Box Climate values) compare to Live Data System #9 corresponding values?

thb0!9press is system pressure and in your example corresponds to (1031.2hPa)
thb0!9seapress is system sea level pressure 1038.4hPa (all things being equal)

thb0!0press which is simply sensor pressure Indoor (Pressure)
and thb0!0seapress Indoor pressure 1038.9hPa (normalized, computed to sea level)

Under [Min/max Data] tab you should notice Pressure, Sealevel pressure, System pressure and System Sealevel pressure, hover mouse over sensor, note the physical sensor & mapping ID and correlate the [Now] value against the [Live Data] tab to match values